QUESTION:
We are trying to enable Client-server mode on a Windows 2003 server and we are getting the following message when tring to connect to the database from any PC:
Error -2147467225: Automation error
The component or application containing the component has been disabled.
PR-Tracker 5.30.0156
Prtr:ConnectNetworkClient Interface:MakePrtrackerObjectInterface() prtracker
ANSWER:
1. Goto the Control Panel, and then click Add or Remove Programs.
2. Click Add/Remove Windows Components.
3. Select Application Server, and then click Details.
4. Click Enable network COM+ access, and then click OK.
5. Click Next, and then click Finish.
After this try to connect to PR-Tracker from the client machine, if you receive any permission error, please perform the following steps:
1. Check the security settings of prtrack.dll file. Make sure prtracker user has full control.
2. Stop the PR-tracker service using the "Component Services" dialog
3. Connect PR-Tracker from the client machine.
|
|
|
|
|

|
| | |
|
|